Skip to Content go to search
Customer Service About Us About Energy Environment Community Investors
Search - click to the Search section
Progress Energy - click to the home page Insulation
En Español    
home > customer service > residential: carolinas > 
 
Insulation/R-Values
 
 
Related Resources
 
 
 
Electric Service
Electric Rates
Pay Your Bill
Products and Services
Save The Watts
Storm Central
Outage Maps
Energy Efficiency and Renewables
Communications
New Movers
My Account (login)
Learn About Registration
Contribute to Renewable Energy
InterConnecting Renewable Sources
Energy Neighbor Fund
Electrical Safety World
Customer Assistance Programs
 
 

"R-value" signifies the ability of a material to resist heat flow. The higher the R-value, the greater the heat flow resistance. For instance, it's more difficult for heat to pass through R-19 insulation than it is to pass through R-11 insulation.

Some materials are naturally better insulators than others. For example, a six-inch batt of fiberglass insulation has an R-value of 19, while an eight-inch concrete block has an R-value of 1.04. Glass, like concrete block, also has little resistance to heat – a single pane of glass has an R-value of 1.13.

The following chart shows average R-values per inch of common insulating materials. Using this chart, you can determine the R-value of a particular amount of insulation from its thickness. For example, 8.5 inches of loose-fill mineral fiber insulation equals R-19. Because R-values per inch vary greatly between different insulating materials, always rate insulation by its R-value and not by inches.

R-Values Per Inch For Common Insulating Materials*

Insulating Material Avg. R-Value Per Inch
Batts or Blankets
  • Mineral fiber (rock, slag or glass)
3.25

Loose Fill

  • Mineral fiber (rock, slag or glass)
2.2
  • Cellulose (milled paper and wood pulp)
3.4
  • Vermiculite, exfoliated
2.13
  • Perlite, expanded
2.7
Rigid Board and Slabs
  • Expanded polystyrene, extruded (cut-cell surface) and molded bead-type
4.0
  • Expanded polystyrene, extruded (smooth-cell surface)
5.0
  • Expanded polyurethane, refrigerant 31 exp.
6.25
  • Polyisocyanurate
7.04
Building Board Sheathing, regular density 2.64

NOTE: Styrene and urethane foams may present smoke- and flame-spread problems if improperly used. Look for UL approval for cellulose. Untreated cellulose is highly flammable.

* R-values from the ASHRAE Fundamentals Handbook. The values given are average R-values. If needed, ask insulation manufacturers for the R-values of insulating materials not listed above.

The table below lists R-values for commonly available thicknesses of residential ceiling, wall and floor insulation:

Insulation Type Inches Needed For:
Ceiling Insulation R-11 R-19 R-22 R-26 R-30
Batts or Blankets
  • Mineral fiber (rock, slag, glass)
3.5 6 6.5 8 9
Loose Fill
  • Mineral fiber (rock, slag, glass)
5 8.6 10 12 13.6
  • Cellulose
3.2 5.6 6.5 7.6 8.8
Frame Wall Insulation R-11 R-19  
Batts or Blankets
  • Mineral fiber (rock, slag, glass)
3.5 6  
CBS Wall Insulation R-3 R-5  
Batts or Blankets
  • Mineral fiber (rock, slag, glass)
.75 1.5  
Rigid Board
  • Polyisocyanurate
.5 .75 *  
  • Expanded Polystyrene (molded bead-type)
1.0 1.5  
Floor Insulation (suspended
frame floors only)
R-7 R-11 R-19  
Batts or Blankets
  • Mineral fiber (rock, slag, glass)
2 3.5 6  
*.50 with 3/4" dead air space


Progress Energy's minimum recommendations for house insulation:

  • In Carolinas:
    • Ceiling: R-30
    • Wall: R-11 to R-19 in frame wall
    • Floor: R-19 in floors 

  


 


width=10
Have Questions?
Review our FAQs or contact our Customer Service Center

 
Customer Service  |  About Us  |  About Energy  |  Environment  |  Community  |  Investors
 
© Copyright 2008 Progress Energy. All rights reserved.    Privacy  |  Legal  |  Sitemap  |  Contact Us